10 Masonry Heater 10.1. Maker. The masonry heater shall be an "EnviroTech" type (Dietmeyer, Ward & Stround, Inc.; P.O. Box 323; Vashon Island WA 98070; 206/463-3722) designed for use with a metal insulated chimney. You shall consult with the maker as required to assure an installation compliant with their design requirements. 10.2. Capacity. The unit shall be the maker's "standard" size. You shall ascertain all dimensions, clearances, and placement requirements from the maker; those shown on the design drawings are tentative, subject to the maker's confirmation. 10.3. Accesories. The unit shall be procured with all accessories appropriate to the installation, such as a long damper handle. 10.4. Veneer. You shall have a qualified mason apply the required 4-inch masonry veneer. The veneer material shall be new, standard-size brick from Mutual Materials Co. in their "Pacific Handmould" color and pattern. The rear wall, facing into the Bedroom, shall have a double-thickness 8-inch veneer. 10.5 Chimney. You shall provide an 8-inch i.d. metal insulated chimney through the ceiling and roof to a height above roof as required by code, covered and capped as required by code and good practice. The chimney shall be very thoroughly flashed where it passes through the roof.